Hanmatek Dos1102 | Manual

While the button is incredibly convenient for beginners—automatically adjusting the vertical scale, horizontal scale, and trigger settings to display an active signal—relying on it exclusively limits your troubleshooting capabilities. Making Manual Adjustments

⚠️ : The DOS1102 is also sold under other brand names (e.g., Hantek, Zeeweii). However, the Hanmatek-specific manual matches the button layout and firmware version most closely.

This comprehensive manual provides the setup steps, core features, and advanced techniques needed to master your device. 1. Unboxing and Initial Hardware Setup

Connect the power cable and press the power button on the top-left of the unit. hanmatek dos1102 manual

Change the vertical scale (zoom in or out vertically). The Horizontal Control Zone

Adjust the Trigger Level knob until the trigger indicator stops flashing.

Vpp (Peak-to-Peak), Vmax, Vmin, Vtop, Vbase, Vavg, and Vrms. This comprehensive manual provides the setup steps, core

: Press [SINGLE] to capture a single transient event. The scope waits for the trigger conditions to be met once, captures it, and freezes the screen.

This guide serves as an in-depth companion, walking you through everything from your first signal capture to advanced measurements.

Moves the waveform left or right across the screen. This shifts your view relative to the trigger point. Change the vertical scale (zoom in or out vertically)

The "hanmatek dos1102 manual" is more than just a PDF file. It is a comprehensive system of resources. By combining the official documentation with this guide, you can move from a beginner user to a confident troubleshooter. Whether you need to master the AutoSet feature, troubleshoot a probe compensation issue, or understand the 1 GSa/s sampling rate, you now have a clear roadmap for unlocking the full potential of your Hanmatek DOS1102 oscilloscope.

Use the multi-purpose knob to move Cursor A and Cursor B to measure the exact difference between two points. 4.3 Setting Up Trigger Conditions Press in the Trigger section. Set Type to Edge . Set Source to CH1 or CH2 . Set Slope to Rising or Falling . Adjust the Level knob to stabilize the waveform. 5. Advanced Functions