Mindray Bc5300 Brochure Pdf Top (2024)
The BC-5300 provides a full white blood cell differential (Neutrophils, Lymphocytes, Monocytes, Eosinophils, Basophils) using advanced cytochemistry and flow cytometry—a major upgrade from 3-part analyzers.
Brochures highlight the technical capabilities that define the analyzer's daily performance and utility.
Supports both whole blood and capillary blood in open vial mode. 5. Why Choose the Mindray BC-5300 Go to product viewer dialog for this item.
The Mindray BC-5300 bridges the gap between compact benchtop analyzers and high-volume floor models. It delivers the diagnostic accuracy of a 5-part differential analyzer while maintaining a small footprint and a low cost of operation. mindray bc5300 brochure pdf top
for a standard CBC, making it ideal for pediatric and geriatric samples.
The BC-5300 utilizes a sophisticated combination of three mainstream technologies to provide reliable 5-part white blood cell (WBC) differentiation:
: For the latest manuals and software revisions, visit the Mindray Technical Documents library. The BC-5300 provides a full white blood cell
Uses a semi-conductor laser to differentiate cells by size and granule complexity. Flow Cytometry (FCM):
| Problem | Possible Cause | Suggested Troubleshooting Step | | :--- | :--- | :--- | | | Contaminated diluent; dirty fluidics path | Run multiple blank cycles; clean probe externally and internally using manufacturer-recommended cleaning solution; replace diluent if contaminated | | Clogged aperture (high impedance errors) | Protein buildup; cellular debris | Initiate automatic cleaning cycle from maintenance menu; if unresolved, perform manual cleaning using the provided aperture cleaning tool with manufacturer-recommended cleaner | | Abnormal WDC differential flags | Inadequate mixing; aged sample (>4 hours old); interfering substances | Remix sample thoroughly and reanalyze; if flags persist, prepare fresh sample; consider performing manual slide review for confirmation | | LIS connectivity failure | Network settings changed; HL7 protocol mismatch | Verify network cable connection; check BC-5300 and LIS server IP addresses/subnet masks; confirm HL7 message format and port number configuration | | Carryover between samples | Insufficient washing between runs | Increase probe wash cycles in software settings; run high-low-normal sample sequence and calculate carryover percentage; contact service if exceed specifications (<0.5% for WBC) | | No power to instrument | Blown fuse; power cord damage; power supply failure | Check power cord integrity and wall outlet; replace fuses with same rating; if unresolved, contact biomedical engineering for power supply testing | | Inconsistent sample volume aspiration | Partially clogged probe; degraded peristaltic pump tubing | Inspect probe tip for visible obstruction; replace peristaltic pump tubing per maintenance schedule (typically every 3-6 months) |
For the full technical layouts and visual guides, you can typically find the brochure on the Mindray official website or through authorized medical equipment distributors [1, 4]. It delivers the diagnostic accuracy of a 5-part
Works in tandem with specialized reagents to accurately identify cell populations. Key Performance Highlights
: Available for download from distributors like Keul.de and Multimedilab .