Siemens.mc.drives.acx.model.configuration Data.package Container Jun 2026
| Error Message | Root Cause | Solution | | :--- | :--- | :--- | | ACX inconsistency: Version mismatch | The container was created with TIA v17, but target project is v15. | Export container in legacy format or upgrade the project. | | Data package container: Missing topology | The container references a drive object (e.g., "Drive_3") that doesn't exist in the hardware configuration. | Use the "Reset topology from actual configuration" wizard. | | Model.configuration invalid: p0922 | The telegram (communication standard) defined in the container does not match the controller's configured telegram. | Check PROFIdrive interface in both PLC and drive. | | Container checksum error | The file was corrupted during transfer (e.g., USB drive removal while writing). | Re-export the container from the original source project. |
: Refers to the internal data model for SINAMICS ACX (common for SINAMICS G/S series drives).
The Siemens MC Drives ACX model is part of Siemens' broader portfolio of variable frequency drives designed to offer precise control over electric motors. These drives are engineered to provide efficient, reliable, and flexible motor control solutions that can be tailored to meet the specific needs of various applications, from simple pump and fan control to more complex industrial processes.
To fix this missing package container error and regain access to your project, execute the following troubleshooting workflow: Step 1: Identify the Required Version Open TIA Portal and attempt to load the project. | Error Message | Root Cause | Solution
Open the TIA Portal Project and go to the . Open the Properties to see the detailed error message indicating which version of the PackageContainer is missing. B. Install/Update SINAMICS Startdrive
: Indicates that the container includes a digital representation or mathematical model of the drive's behavior and structural limits.
siemens.mc.drives.acx.model.configuration data.package container | Use the "Reset topology from actual configuration" wizard
Siemens provides various software tools for configuring and commissioning their drives, such as:
For further information, refer to Siemens official documentation on SINAMICS drives, Create MyConfig (CMC), and the SINAMICS Drives LIB programming interface. The Siemens Industry Support portal provides additional resources, including manuals, application examples, and troubleshooting guides.
// Apply to a SINAMICS S120 device using (var drive = new SinamicsDevice("192.168.1.10")) | | Container checksum error | The file
In the context of Siemens drive configuration, a data package container likely refers to a structured collection of data and parameters used for configuring, monitoring, and controlling a drive. This can include:
Traditional drive backups were limited to parameter lists or memory card images. With the siemens.mc.drives.acx.model.configuration data.package container , you can integrate drive configuration directly into your PLC project’s version control system (e.g., Git, Siemens Version Control Interface). The container stores the entire “as commissioned” state, allowing point-in-time recovery of complex motion systems.
C. Install Specific Toolboxes (For SINUMERIK/SIMATIC Drives)
When we look at the string siemens.mc.drives.acx.model.configuration data.package container , we can break it down into its functional parts:
If an error related to Siemens.MC.Drives.Acx.Model.Bico.PackageContainer occurs (often indicating ), several troubleshooting steps are available: