Lenel Lnl3300m5 Installation Manual Upd Top ((exclusive)) Jun 2026

By default, the board may be set to DHCP or a default static IP (check the manual for current default settings).

12 to 24 VDC ± 10%, 150 mA maximum (plus reader current).

To configure the unit for the first time via its web interface: Direct Connection : Set your computer's IP address to 192.168.0.2 (or any address in that range except DIP Switch Settings DIP switch 2 to ON (with 1, 3, and 4 OFF) to enable configuration mode. Accessing the Panel : Power cycle the unit and navigate to

Form-factor compliant with legacy Software House MR50 enclosures for seamless mechanical drop-in replacement. 📐 Board Layout and Component Identification lenel lnl3300m5 installation manual upd top

Illuminate when raw card data packet transactions occur.

Wire readers according to the specific configuration required (e.g., Reader 1, Reader 2). Downstream Device Communication (SIOs)

This comprehensive installation guide provides the technical steps, wiring configurations, and dip switch settings required to successfully deploy and update the LNL-3300-M5 controller. 1. Product Overview and Technical Specifications By default, the board may be set to

Enter the configured IP address in the communication settings tab. Set the appropriate download parameters and click .

Before beginning the physical installation, ensure your environment meets the necessary requirements: 12 to 24 VDC ± 10%, 500 mA maximum.

Use the existing ribbon cables or screw terminals to connect to inputs and outputs, ensuring shielded cable is used for card reader connectivity to minimize interference. 5. Summary Table (LNL-3300-M5) Specification Input Power 12 VDC @ 300mA (nominal) Dimensions Operating Temp -65°F to 185°F (-55°C to 85°C) Downstream Devices Up to 64 devices (Input, Output, Reader modules) Communication 10/100 Ethernet (AES-128 Encryption) Accessing the Panel : Power cycle the unit

: After configuring the desired network settings, turn all DIP switches OFF , navigate to the "Apply Settings" page, and click Apply settings and reboot .

Verify that the RS-485 polarity (TR+ and TR-) is not reversed. Ensure that the DIP switch configurations on the legacy panels match the expected addressing scheme in the OnGuard software.

: Plug the field wiring into the new Lenel M series board. It is plug-compatible with the 12 VDC power input, cabinet tamper input, and AC power fail input from the legacy Power/Comm Board.